INTRODUCTION
WARNING: THIS APPLIANCE MUST BE EARTHED
RATING PLATEThe cable must be routed away from potentially hot
areas marked by X in the diagram below.
This is situated on the front frame of the appliance
and can be seen upon opening the door.
Alternatively the rating plate may also be found on
the back or top of some models (where applicable).
The appliance must be protected by a suitably rated
fuse or circuit breaker. The rating of the appliance is
given on the rating plate.
Do not remove the rating plate from the appliance
as this may invalidate the guarantee.REAR VIEW
To move the appliance, open the main oven door,
and lift the appliance by holding inside the top of the
INSTALLATION
compartment.
If your appliance has been damaged in transit,
contact your supplier immediately. DO NOT attempt
to install it.
Your appliance left the factory fully packaged to
protect it from damage. If it is delivered without
packaging and damage has occurred, the
manufacturer cannot accept responsibility. Contact
your supplier for advice.
Once the packaging has been removed the appliance
should only be moved by hand. DO NOT use a sackThis is a type Y appliance which means it is free-
barrow or any other aid to lift the appliance asstanding and can be fitted with cabinets on one or
damage may occur.both sides. It may also be fitted in a corner setting.
Connection to the electricity supply must be carriedEnsure that the appliance is standing level.
out by a qualified electrician/competent person.
Side walls which are above hob level should be
The electrical connection should be made using aprotected by heat resistant non-combustible material
double pole isolating switch (cooker socket) with atand MUST NOT be nearer than 40mm to the hob
least 3mm contact separation in all poles. The cableside.
must have conductors of sufficiently high cross-
sectional area to prevent overheating andA nominal air gap of 2mm all around the appliance is
deterioration.required to enable the appliance to be moved into
position.
The recommended cross-section area is six square
2
millimetres (6.00mm).Always ensure an air gap is maintained at hotplate
level. Tiles or other forms of deep wall covering
should not obscure this gap.
Air gap
8 |